7/8 inch Cellflex is a quarter of the price of RG393, good for 12.3kW on 6m,
but hard to use as a rotator loop, more then double the diameter and far
smaller bending radius.
73
Peter
-----Original Message-----
From: TowerTalk [mailto:towertalk-bounces@contesting.com] On Behalf Of Jim
Brown
Sent: Dienstag, 3. November 2020 19:37
To: towertalk@contesting.com
Subject: Re: [TowerTalk] Where to get LMR 400
On 11/3/2020 9:32 AM, dj7ww@t-online.de wrote:
> Yes, the current heats up the dielectric around the center conductor.
> RG393 with the same conductor size and its PTFE dielectric is specified at
> 9500W on 6m.
If I were to spend that money, it would be on hard line, which has lower
loss and better shielding.
73, Jim K9YC
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|