Rick,
This has been discussed here in the past. IIRC, the consensus was that most
name-brand F6 and RG-6 coax with a CCS center conductor has a sufficiently
thick coating of copper for 160m. The difference between solid copper and
CCS is well under 1 dB.
Type the following into Google to access some of that info:
site:contesting.com RG-6 CCS loss 160
73, Mike
On Mon, Mar 16, 2015 at 12:39 AM, Richard (Rick) Karlquist <
richard@karlquist.com> wrote:
> Most RG-6 has a copper clad steel center conductor.
> Does anyone have data on what the loss of this
> type of cable is at 1.8 MHz compared to solid
> copper center conductor? Any suggestions
> for RG-6 with a solid copper center conductor?
> I see Belden 1694A, 7915A, 7916A and 9248 in
> the catalog, but don't know if any of this is
> available in distribution. Can anyone suggest
> some good distributors to buy quality RG-6?
> Thanks.
>
> Rick N6RK
> _________________
> Topband Reflector Archives - http://www.contesting.com/_topband
>
_________________
Topband Reflector Archives - http://www.contesting.com/_topband
|