Do you really need the fourth wire if there is a ground / case lug on
the back of the amp tied to your station ground ? W4DNR
On 2022-12-30 1:36 pm, gudguyham--- via Amps wrote:
Roger just use the CT of the primaries for a neutral No reason to run
more wires.
Sent from the all new AOL app for iOS
On Friday, December 30, 2022, 2:15 PM, Roger Parsons via Amps
<amps@contesting.com> wrote:
Afraid this is an additional question rather than an answer...
This thread has induced me to do what I have been meaning to do for
ages. I have an old PT3000 (yes, that is the correct number) amp which
has ground and neutral tied together internally as well as a few 120V
components. So a four wire connection seems to be the safest solution.
Plug and receptacle easy - 20A twistlock. (Don't think 15A is
available.)
Cable not so easy. All I can easily get here is SOOW which in 12/4 is
about the thickness of an elephant's trunk. I can order SJOOW which is
better but still pretty thick. Both those cables are intended for
industrial use. I can't find any consumer type indoor cable. Does such
an animal exist?
73 Roger
VE3ZI