The discussion pertained to relay connections in the matching network
for a HF vertical antenna.
73, Alek, VK6APK
On 28/07/2021 7:07 am, Jim wrote:
But there is no lightning inside of an amplifier... Hopefully. :)
Thanks
73
Jim W7RY
On 7/26/2021 12:59 PM, Jim Brown wrote:
I don't understand this concern. Vacuum relays have been widely used
for decades for antenna switching in power amps, where the impedance,
and thus voltage and current, are the same as for this application.
What am I missing?
73, Jim K9YC
On 7/26/2021 3:08 AM, Rob Atkinson wrote:
I would not use a vacuum relay in a matching network for a 1/4 w.
antenna. That's a low v. high current setup calling for open frame
contactors or at least large open relays. Perhaps this information
will render your question moot.