I prefer vacuum relays outside, they are immune to corrosion and not that
expensive when ex military stock from Russia like B1B or B2B SPST types.
73
Peter
-----Original Message-----
From: Amps [mailto:amps-bounces@contesting.com] On Behalf Of Aleksandar
Petkovic
Sent: Dienstag, 27. Juli 2021 02:00
To: amps@contesting.com
Subject: Re: [Amps] Vacuum Relay Question
I think that the point was that the expensive vacuum relay could be
replaced by a much cheaper open frame relay arrangement in this
application, where high impedance/voltage is not in the equation.
Tens of dollars versus hundreds of dollars makes good sense when the
lightning comes to town.
73, Alek, VK6APK
On 27/07/2021 1:59 am, Jim Brown wrote:
> I don't understand this concern. Vacuum relays have been widely used
> for decades for antenna switching in power amps, where the impedance,
> and thus voltage and current, are the same as for this application.
>
> What am I missing?
>
> 73, Jim K9YC
>
> On 7/26/2021 3:08 AM, Rob Atkinson wrote:
>> I would not use a vacuum relay in a matching network for a 1/4 w.
>> antenna. That's a low v. high current setup calling for open frame
>> contactors or at least large open relays. Perhaps this information
>> will render your question moot.
>
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|