Maybe even better; the type of plumber dope they use to seal the threads.
What I don't like with the PL-259 is the lack of springs to keep the connection
good at the screen side. All other connectors have some type of spring that
ensure a good connection such as BNC and N. You have to tighten the PL-259
"well" in order to keep a good contact and there are no insurance they will
losen up over time.
Hans - N2JFS
-----Original Message-----
From: Kris Mraz <n5kilomike@gmail.com>
To: towertalk <towertalk@contesting.com>
Sent: Mon, May 25, 2015 6:19 pm
Subject: Re: [TowerTalk] sealing PL259's
What about plumber's Teflon tape?
Kris
N5KM
-------------------------------------------------
Jim K9YC said:
On
Mon,5/25/2015 4:45 AM, Marsh Stewart wrote:
> Timely question. I've been
wondering about how to waterproof the shell of a
> PL259 to the flange of an
SO239.
I use Scotch Mastic tape, 2228.
73, Jim
K9YC