I think Ian has expressed the main reason for the "Back-desk-grounding-rod".
The word "grounding" should be avoided as a connection to the ground/earth is
not that essential. Getting the different "boxes" connected together is what we
want. That will reduce RFI/EMI and will help protecting the equipment from
power surges.
Hans - N2JFS
-----Original Message-----
From: Ian White <gm3sek@ifwtech.co.uk>
To: towertalk <towertalk@contesting.com>
Sent: Sat, Mar 22, 2014 5:41 am
Subject: Re: [TowerTalk] Back of desk grounding buss
One more time: the main purpose of the strip along the back of the desk
is to ensure that all the equipment metalwork is closely connected
<together> at all frequencies from DC to RF. The best term for this is
"BONDING".
(Thoughtful authors try to avoid calling it "grounding" or "earthing"
because a connection to the Mother Planet is not the main aim. You
should connect the bonding strip to a mains safety ground as well, but
that was not your main reason for having the bonding strip.)
73 from Ian GM3SEK