To: | towertalk@contesting.com |
---|---|
Subject: | Re: [TowerTalk] Back of desk grounding buss |
From: | Kevin Stover <kevin.stover@mediacombb.net> |
Date: | Thu, 20 Mar 2014 13:29:26 -0500 |
List-post: | <towertalk@contesting.com">mailto:towertalk@contesting.com> |
I use a eight foot length of one inch copper water pipe.I drilled holes in it every eight or so inches and installed #8 stainless bolts with inside tooth locks against the copper. Everything in the shack is tied to that buss which is tied to the entrance ground outside, near where the panel is in the basement, with #4 solid copper. -- R. Kevin Stover AC0H ARRL FISTS #11993 SKCC #215 NAQCC #3441 _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |