TenTec
[Top] [All Lists]

Re: [TenTec] Omni six-- heat related IF gain problem

To: Barry Gross <barry.n1eu@gmail.com>,Discussion of Ten-Tec Equipment <tentec@contesting.com>
Subject: Re: [TenTec] Omni six-- heat related IF gain problem
From: Ken Brown <ken.d.brown@verizon.net>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Wed, 13 Jul 2005 14:11:26 -1000
List-post: <mailto:tentec@contesting.com>
>>This is the first I've heard of anyone installing cooling fans in the Omni 6. 
>>    
>>
>
>
>Actually, this wasn't an uncommon topic a few years back.  Personally,
>I found that my PBT settings were shifted dramatically during cw
>contesting due to internal heat buildup.  I used an external fan
>blowing on the rear heatsink which seemed to help, but the internal
>cooling fan always seemed a good solution to me.
>  
>
I find that operating my Omni VI in CW contests a fan on the PA heat 
sink is necessary. My Kenwood TS-440 has a built-in fan with temperature 
controlled speed, or at least duty cycle. The TS-440 receiver 
performance in contest conditions does not compare to the Omni VI 
though. I wish Ten-Tec would have included a built in fan. I have never 
tried, or thought that I needed, a fan to ventilate the insides of the 
Omni VI though.

Okay now you can flame me for saying that a JA rig has a usefull feature 
that is not in a Ten-Tec.

DE N6KB