Thanks for the feedback!
I am still on the clock at work but took a break to check R8 and I am seeing
3.98K ohms, so the 4k resistor seems intact. Later tonight when finally done
with work I will tear into it to look at the fuses and other resistors, confirm
there is REALLY 220 v getting to the unit, and anything else that comes up.
Thanks all for the ideas!!!!
David
N1RO/VE3TMK
> On Nov 8, 2022, at 2:33 PM, gudguyham@aol.com wrote:
>
> Did you check R8 for open?
>
>
> Sent from the all new AOL app for iOS
> <https://apps.apple.com/us/app/aol-news-email-weather-video/id646100661>
>
> On Tuesday, November 8, 2022, 2:20 PM, David Tenenbaum <dmt013@gmail.com>
> wrote:
>
> Hi All,
>
> I have an Alpha 86 that I have been using set up for 110v, and finally have
> access to 220v, so looking forward to seeing what it can REALLY put out.
> Unfortunately I have made the jumper changes (terminal in the back for 110
> operation has locations 1&2 jumpered, 3&4 jumpered, and 5&6 jumpered, but for
> 220 only locations 2&3 are jumpered), and the unit fails to light up or come
> online. I hear a single relay activation when I hit the "On" switch, but no
> lights or fan.
>
> Fearing I hurt the unit I restored it to 110v operation and all is good. I
> set it back to 220v and same problem. I checked continuity from the plug's
> ground to chassis ground, and the hot leads show continuity to the right
> places. I have been using a 220v SB200 on that outlet just fine.
>
> Any thoughts or leads appreciated! Never thought I would have a problem just
> switching supply voltages.....Scan of schematic attached....
>
> Best,
>
> David
> N1RO/VE3TMK
> _______________________________________________
> Amps mailing list
> Amps@contesting.com <mailto:Amps@contesting.com>
> http://lists.contesting.com/mailman/listinfo/amps
> <http://lists.contesting.com/mailman/listinfo/amps>
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|