TenTec
[Top] [All Lists]

Re: [TenTec] RFI Issues

To: tentec@contesting.com
Subject: Re: [TenTec] RFI Issues
From: Jim Brown <k9yc@audiosystemsgroup.com>
Reply-to: k9yc@arrl.net, Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Wed, 16 May 2012 19:49:03 -0700
List-post: <mailto:tentec@contesting.com>
On 5/16/2012 12:22 PM, Stuart Rohre wrote:
Likely with a second floor shack, ONLY the tuned ground lead would help your 
RFI.

Repeat after me:

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

What matters is proper bonding of cable shields to the chassis of the equipment to which it is connected, and the proper bonding of every equipment chassis to each other.

73, Jim K9YC

<Prev in Thread] Current Thread [Next in Thread>