On 5/15/2012 10:58 PM, Pa1ap wrote:
The question I have: could I have done this easier through applying other 
techniques like described in the document? am I just fixing a sympthom instead 
of the root cause? I had two rfi issues; potential rfi into the mic and rfi 
into the audio equipment within the house. I am new in this area.

Yes, a so-called "artificial ground" is a really bad idea. Proper bonding together of chassis to chassis and to all earth grounds within a home or building, including mains power, telephone, satellite, cable TV, and antennas is the only right way to do it.

73, Jim K9YC