Onno,
Likely with a second floor shack, ONLY the tuned ground lead would help your RFI.

That is because, as you state, your station in in the near field (close to apex) of the antenna.

You are likely so far above Earth ground that it would be hard to not have radiation off a long ground lead even if made of flat copper ribbon.

And, most places, the Earth soil is a poor, poor conductor of RF and NOT suited for an RF ground.

Use of the tuned ground wire lead, insulated from other grounds, is the first step as you took it.

The use of choke cores, is a valid and broadband solution to remaining RF feeding back on cables.

You have done well for your station, and now have RF neutral chassis.
Good Work and enjoy good DX.

Stuart Rohre