Low or no output on a band or bands can be dirty switch contacts. 10, 12, and 15 haven't had much use in the past few year. It might be a quarter drop of deoxit on each contact with some vigorous switch operation might clean them up, or the problem could be a poor solder joint that went open or nearly open.
The Omni VI uses diode switching for all of that. I don't think there is a single mechanical switch contact (besides the band select push button) involved with the band selection. If it indicates that it has switched to the band you want, then that pushbutton is working fine. The parallel band select lines that go to various boards may need cleaning and the bad solder joint is a possibility.

Its not possible to be more specific because there can be so many ways to loose a band or bands (and the crystal is not above suspicion nor the crystal socket when crystals are used to heterodyne the VFO) unless one has repaired many Omni VI with the same problem. I doubt there's any RF difference between VI and VI+.
Omni VI does not use crystal sockets. A bad crystal, or misaligned inductor in the crystal oscillator circuit could be the cause. Don't mess with those inductors unless you have the right equipment to get yourself out of the trouble you may cause. The locations of the coils used for each band is not immediately obvious, and there is a good chance you'll end up adjusting one that did not need adjusting. Make sure you use the perfectly shaped soft plastic twiddle stick for the inductor slug or you will likely break the slug. You will need an oscilloscope with a high impedance probe (like a 10 X probe that only loads the circuit with 10 Meg ohms + small capacitance) to monitor the PLL loop in order to properly set those slugs. And when you have that equipment, the description of the waveform you are looking for is more than I'm prepared to put in this message.

DE N6KB