A correction to my previous post:

I said:
>  Once the internal collector metering is and forward power metering is 
> calibrated, you can adjust the OVERDRIVE trigger levels.
>   
I meant to say:

Once the internal collector current metering and forward power metering is 
calibrated, you can use the internal metering as a reference to adjust the 
OVERDRIVE LED trigger levels.

The LED bar graph power output indicator is also adjustable. It is no more 
accurate than the meter, although it may respond faster to peaks. 

If the OVERDRIVE LED is coming on at only 300 watts output, I would not trust 
any of those adjustments to be correct. It is likely that someone has already 
been in there mis-adjusting things.