Yes for years most companies have adopted the 6 dB per S unit and the 50 uV 
for S-9 on HF.  Collins some years ago used the 100 uV for S-9.

And then for some companies, a signal of some value caused the S meter to 
move upscale to some value.  Then more signal caused it to move upscale 
more.

Fortunately most companies today do adhere to and have adopted the 50 uV for 
S-9 as the standard and one S unit change is 6 dB signal change.

73
Bob, K4TAX


----- Original Message ----- 
From: "philip c anderson" <flypca@hotmail.com>
To: <tentec@contesting.com>
Sent: Tuesday, January 08, 2008 10:05 AM
Subject: [TenTec] STANDARDISATION OF S-METER READINGS



I hope I do not over step the purpose of this site but after all of the 
dicussions about the isolation between Ant 1 and Ant 2 I thought that the 
enclosed info might help put some actual values to the "S" meter readings.
I am sending a 2nd mail with more info fromanother source.>> > IARU Region 1 
Technical Recommendation R.1> BRIGHTON 1981, TORREMOLINOS 1990> Page 1 of 1> 
 > > STANDARDISATION OF S-METER READINGS> > 1. One S-unit corresponds to a 
signal level difference of 6 dB,> > 2. On the bands below 30 MHz a meter 
deviation of S-9 corresponds to an> available power of -73 dBm from a 
continuous wave signal generator connected> to the receiver input 
terminals,> > 3. On the bands above 144 MHz this available power shall 
be -93 dBm,> > 4. The metering system shall be based on quasi-peak detection 
with an attack> time of 10 msec ± 2 msec and a decay time constant of at 
least 500 msec.> > > http://www.algonet.se/~k-jarl/ssa/IARU/smeter.html> > 
For a 50 ohm systems this means S-9 is 50uV for HF and 5uV for VHF/UHF.> >
_________________________________________________________________
Put your friends on the big screen with Windows Vista® + Windows Live™.
http://www.microsoft.com/windows/shop/specialoffers.mspx?ocid=TXT_TAGLM_CPC_MediaCtr_bigscreen_012008
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec 


_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>