Folks, Here are some figures measured on my Corsair II: 160m: S6 = -90dBm, S9 = -68dBm (89uV), S9+20 = -47dBm 80m: S6 = -90dBm, S9 = -70dBm (71uV), S9+20 = -49dBm 40m: S6 = -90dBm, S9 = -68dBm (89uV), S9+20 = -47dBm 20m: S6 = -95dBm, S9 = -72dBm (56uV), S9+20 = -50dBm 10m: S6 = -95dBm, S9 = -72dBm (56uV), S9+20 = -50dBm Average dB/Spoint is 7.3 between S6 and S9 across all bands. S9 to S9+20 averages 21.6dB across all bands. RF attenuator measures 15dB on all bands. Not too bad for an "old un" Steve G3TXQ _______________________________________________ TenTec mailing list TenTec@contesting.com http://lists.contesting.com/mailman/listinfo/tentec |