| To: | Discussion of Ten-Tec Equipment <tentec@contesting.com> |
|---|---|
| Subject: | Re: [TenTec] Orion II S Meter |
| From: | "Martin, AA6E" <martin.ewing@gmail.com> |
| Reply-to: | Discussion of Ten-Tec Equipment <tentec@contesting.com> |
| Date: | Wed, 28 Dec 2005 15:09:30 -0500 |
| List-post: | <mailto:tentec@contesting.com> |
A quick check is to tune in a steady S9 carrier and then switch in 6, 12, and 18 dB attenuation. That should give you S8, S7, S6, respectively. I've found pretty fair agreement on my (classic) Orion. 73 Martin AA6E On 12/28/05, Barry Gross <barry.n1eu@gmail.com> wrote: > As Phil measured, the meter is overly dramatic above and below s9 - here's > correct readings with actual readings in parentheses > > uV S-Meter > > 5 s5.7 (s3) > 15 s7.3 (s6) > 50 s9 > 150 s9+10dB (9+20dB) > 500 s9+20dB (9+35dB) > 1500 s9+30dB (9+45dB) > 5000 s9+40dB (9+55dB) > -- martin.ewing@gmail.com http://blog.aa6e.net |
| <Prev in Thread] | Current Thread | [Next in Thread> |
|---|---|---|
| ||
| Previous by Date: | Re: [TenTec] CVS TDE headphones, Mike Hyder -N4NT- |
|---|---|
| Next by Date: | Re: [TenTec] CVS TDE headphones, John Graves |
| Previous by Thread: | Re: [TenTec] Orion II S Meter, Barry Gross |
| Next by Thread: | [TenTec] Orion 2 - S meter, Ken Waites |
| Indexes: | [Date] [Thread] [Top] [All Lists] |