You got it. The extra 35 ohms is all loss resistance, heating up the worms.
Add radials.

K0SN


On Sat, Mar 15, 2025 at 6:52 PM WW3S <ww3s@zoominternet.net> wrote:

> what should the impedance be? I thought I read somewhere ideally around
> 36-40 ohms...testing my new 30m vertical showed around 75 ohms, and
> mostly flat for 2 meg or more, which I seem to recall is really not the
> best...am I correct that while a wide bandwidth seems good, it really
> isnt, I think maybe its telling me the radial system needs improved?
>
> 73