Towertalk
[Top] [All Lists]

Re: [TowerTalk] 4 square question

To: kq2m@kq2m.com, towertalk@contesting.com
Subject: Re: [TowerTalk] 4 square question
From: Alan Swinger <awswinger@earthlink.net>
Reply-to: Alan Swinger <awswinger@earthlink.net>
Date: Sun, 18 Oct 2020 14:55:19 -0400 (GMT-04:00)
List-post: <mailto:towertalk@contesting.com>
Per my DX Eng Guide used to construct my 40M 4 Sq and in daily use, radiation 
is on the diagonals . .. not broadside. - Alan K9MBQ


-----Original Message-----
>From: kq2m@kq2m.com
>Sent: Oct 18, 2020 2:49 PM
>To: towertalk@contesting.com
>Subject: [TowerTalk] 4 square question
>
>Hi,
>
>I will be rebuilding several 4-squares this season as well as restringing them 
>in different trees due to Tornado damage (loss or destruction of many trees at 
>my qth) during Tropical Storm Isaias on August 4th.  I have a few questions 
>for which I would appreciate your guidance....
>
>1) If I recall correctly, for purposes of focusing on Europe, ideally I would 
>want to put the 4 elements in a box formation in the NE, SE, SW and NW 
>directions relative to the middle of the array.  Is that correct?
>
>2) In the 4-square when I select the controller direction NE, I am effectively 
>radiating broadside NE from the NW and SE elements.  Is that correct?
>
>3) In the past I had the bottom of the 4-square elements soldered to center 
>conductor of the pin of an SO239 with the radials attached to each of the 
>SO239 screw holes, with the coax connector for the phasing line screwed onto 
>the SO239.   (The choke was located below the PL259 on the phasing line) This 
>worked well but I am trying to improve the design.
>
>If I were to terminate the bottom of the 4-square element by twisting it 
>through and around one hole of the porcelain insulator and soldering it there, 
>would I still be able to then solder a small wire from that connection to the 
>center conductor pin of a SO239 with the radials attached to the SO239 screw 
>holes as before?  My idea being that I can do that then I can use a piece of 
>twine through the remaining porcelain insulator hole taped to the coax to 
>provide additional physical support for the coax and radials – which will be 
>helpful during ice storms.
>
>I would appreciate any thoughts and suggestions and possible improvements on 
>this design.
>
>Tnx  & 73
>
>Bob, KQ2M
>_______________________________________________
>
>
>
>_______________________________________________
>TowerTalk mailing list
>TowerTalk@contesting.com
>http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
<Prev in Thread] Current Thread [Next in Thread>