The capacitance per ft and simple arithmetic will get you a DC capacitance value that is reliable but add in frequency of the applied voltage and inductance rears its head. As per others, you get a stub, not an idealized capacitor.

Patrick        NJ5G


On 6/25/17 11:18 PM, jimlux wrote:
On 6/25/17 3:52 PM, Tom Osborne wrote:
Hi All

This might seem like a silly question, but is it possible to make a 150pf capacitor out of RG-58? Thanks and I need one for an EFHW I am building.

Sure.. 25 pF/ft, so 6 ft.