On 6/25/17 4:20 PM, David Robbins wrote:
Yes, rg58 should be about 40pf/ft.  just beware, if the length becomes a
significant fraction of a wavelength then you have to calculate the
impedance based on the length and velocity factor.


My table said 25 pF/ft.  RG-8/rg-213 is 13pF/ft


So, moral of the story is, check for the brand of your coax, and use the appropriate length.