I use 3M ITCSN-0800  heat shrink with adhesive in it.  It will seal any
outside coax connection.  It can be purchased at an electrical supply store.

Bill / W4WEG

-----Original Message-----
From: TowerTalk [mailto:towertalk-bounces@contesting.com] On Behalf Of Mike
Rhodes
Sent: Monday, November 03, 2014 11:09 AM
To: TowerTalk@contesting.com
Subject: Re: [TowerTalk] Adhesive lined heat shrink for connectors

Thanks for the suggestions Tom. I tried searching for 'flooded' heat shrink
but found I had better luck searching for 'lined' heat shrink.

Mike / W8DN

On 11/3/2014 10:23 AM, Tom LeClerc W1TJL wrote:
> I bought a bunch of this in various sizes for various coax / hardline 
> sizes for a VERY good price off eBay.  Works great and so far the 
> results have been what I expected.  In addition to waterproofing the 
> back end it helps support and stiffen the coax to connector joint.  I 
> have it in sizes from 1/8 inch to over 2 inches (all pre-shrunk 
> sizes).  Be aware that there are also various degrees of shrinkage 
> available.  Some shrink 2 to 1 and some 3 to 1 and there may be even 
> more.
>
> I searched on the word Flooded Heat Shrink to find it...
>
> 73, Tom W1TJL
>
> On Mon, Nov 3, 2014 at 9:23 AM, Byron Tatum <bjtatum1@att.net> wrote:
>> Hello-
>>     I am preparing some feedlines for my two towers and the installation
of about 10 tower mounted (mostly VHF/UHF) antennas. I will be using 1-5/8",
7/8" and 1/2" heliax, all going back to N-type connectors on RG-214/U rotor
loops; plus some LMR-400 coaxial connectors on the masts.
>>    I installed some 7/8" heliax connectors that came with adhesive lined
heat shrink and I really like it. The heat shrink sealed the connector to
the cable. I wish to buy some of the same for all of my connectors, plus
some to cover the entire junction of various cables. The greatest OD change
I have is from 1-5/8" heliax (2.5" OD connector) down to an N-connector on
RG-214/U (0.81"). I see some 3:1 and 4:1 adhesive lined heat shrink on ebay
(from overseas) but thought I would ask what is the best brand or type and
where to get it.
>>    Thanks all, Byron WA5THJ
>> _______________________________________________
>>
>>
>>
>> _______________________________________________
>> TowerTalk mailing list
>> TowerTalk@contesting.com
>> http://lists.contesting.com/mailman/listinfo/towertalk
>
>

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>