This is not always correct.  My Rohn 65G guy brackets 
http://www.dxengineering.com/parts/roh-ga65gd only attach to one leg.

John KK9A


To:     towertalk@contesting.com
Subject:        Re: [TowerTalk] Guyed + self supporting /2 ??
From:   "Roger (K8RI) on TT" <K8RI-on-TowerTalk@tm.net>
Date:   Wed, 15 Oct 2014 03:08:40 -0400

<snip>

Guys should NOT attach directly to the tower legs! This weakens the tower,
by applying a lateral force to only one leg. ROHN has a guy attachment
saddle that fits AROUND the tower. The saddle absorbs lateral forces,
while vertical forces are transferred to the tower. Look at the ROHN site
for proper guy attachment.