True, only on one leg for Rohn 65 brackets, and they should be attached at a Z brace weld as shown. They come with a (not quite a U) u-bolt specially made for going around the leg and the 5/8" bracing rods. Unobtainium except from Rohn.

The principal is to transfer the horizontal loads to all R65 legs via the bracing. The 25/45/55 Z braces must need the extra strength of the guy bracket ("mounts to tower at any horizontal brace" per Rohn).

Grant KZ1W


On 10/15/2014 3:58 AM, john@kk9a.com wrote:
This is not always correct.  My Rohn 65G guy brackets
http://www.dxengineering.com/parts/roh-ga65gd only attach to one leg.

John KK9A


To:     towertalk@contesting.com
Subject:        Re: [TowerTalk] Guyed + self supporting /2 ??
From:   "Roger (K8RI) on TT" <K8RI-on-TowerTalk@tm.net>
Date:   Wed, 15 Oct 2014 03:08:40 -0400

<snip>

Guys should NOT attach directly to the tower legs! This weakens the tower,
by applying a lateral force to only one leg. ROHN has a guy attachment
saddle that fits AROUND the tower. The saddle absorbs lateral forces,
while vertical forces are transferred to the tower. Look at the ROHN site
for proper guy attachment.

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk


_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>