I have used a number of the Polyphaser and DX Engineering ground clamps.
Unfortunately they are designed for 0.625" ground rods which seems to be
impossible to find. Most 5/8 ground rods typically measure 0.562 so to use
these clamps you need to make a shim. You also need to notch the 2" wide
strap to clear the bolts.
John KK9A
To:TowerTalk <TowerTalk@contesting.com>
Subject:[TowerTalk] Connecting Flat Copper to 5/8" Ground Rod
From:Ray Benny <rayn6vr@cableone.net>
Date:Sun, 13 Oct 2013 14:47:23 -0700
Has anyone come up with a way to connect flat copper straps to ground rods?
DXXE sells copper clamps w/ hardware, but at $35 a pop, I hoping that there
is a more reasonable way to get the job done.
My copper strap is 2" wide, by 6ft, and about 18 ga, but not sure.
Tnx,
Ray,
N6VR