Totally agree with Jake, I suspect this is the problem.
This has happened to me also.
I have put another slot with a hacksaw opposite the original slot as Jake said.
Works great.
73,
Bob
K6UJ
On Jan 27, 2013, at 8:35 AM, jcjacobsen@q.com wrote:
> How do to all,
>
> Jerry is having a "problem" with hose clamps on tubing.
>
> Jerry,
> When you get the clamp close to tight take a look at the slit in the tubing.
> Are the two sides pinched together?? My experience is if the slit isn't wide
> enough the sides will pinch and no amount of tightening will work.......
> strip city of the clamp, if you will. My approach is either widen the slit,
> or use a hacksaw to make another slit opposite the first. It works for me.
>
> 73 es GDDX
> K9WN Jake
>
>
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com