Larry:
It depends. I have my Polyphasers at the NEMA box at the tower base,
but I also have a remote coax switch there, too. I connected the
Polyphasers between the coax and the switch so that each coax was
individually protected BEFORE it went into the switch. If I had mounted the
switch in the shack, I would have put the Poly's outside the shack directly
on the SPG panel.
Don't forget to ground the shields of your coax at the top and bottom
of the tower, too.
73 de
Gene Smar AD3F
----- Original Message -----
From: "Larry Boekeloo" <lboekeloo@sbcglobal.net>
To: <towertalk@contesting.com>
Sent: Friday, September 10, 2010 8:09 PM
Subject: [TowerTalk] Lightning Protection Question
My new tower is 200 feet from my new (unbuilt) shack. Should I put the
polyphasers at the tower in the NEMA box or at the shack in the NEMA box or
does it not matter. There is a ground cable between the two and I'll have a
SPG when complete.
Thanks.
Larry, KN8N