At the base of the tower with a good path to a ground system at the tower is
better.  Best would be to also have a perimeter ground at the shack and
another protector at the entrance.

73 John N5CQ


-----Original Message-----
From: towertalk-bounces@contesting.com
[mailto:towertalk-bounces@contesting.com] On Behalf Of Larry Boekeloo
Sent: Friday, September 10, 2010 7:10 PM
To: towertalk@contesting.com
Subject: [TowerTalk] Lightning Protection Question

My new tower is 200 feet from my new (unbuilt) shack.  Should I put the
polyphasers at the tower in the NEMA box or at the shack in the NEMA box or
does it not matter.  There is a ground cable between the two and I'll have a
SPG when complete.
 
Thanks.

Larry, KN8N