I use a section of stainless steel (good quality). Wrap it around the
leg, then use a stainless steel hose clamp to hold your copper wire in
place against the stainless steel "plate". Works well - no signs of
corrosion in the 6 years it's been in place.
73,
Joe
WDØM
Pagosa Springs, CO
HTTP://www.wd0m.com
K7LXC@aol.com wrote:
>
> In a message dated 8/2/2009 12:01:10 P.M. Pacific Daylight Time,
> towertalk-request@contesting.com writes:
>
>
>> What is the best way to bond grounding conductors to Rohn 25,45,or 55?
>>
> I am ok with cadweld for the rods etc but is cadweld the answer for
> bonding to the tower section?
>
> No. Do not use Cadweld on the tower - it'll just burn a hole in the
> thin wall of the leg. Use a compressive mechanical bond of some sort. People
> have already mentioned the Polyphaser TK. It works great.
>