In a message dated 8/2/2009 12:01:10 P.M. Pacific Daylight Time,  
towertalk-request@contesting.com writes:

>  What is the best way to bond grounding conductors to Rohn  25,45,or 55?  
I am ok with cadweld for the rods etc but is cadweld the  answer for 
bonding to the tower section?
 
    No. Do not use Cadweld on the tower - it'll just  burn a hole in the 
thin wall of the leg. Use a compressive mechanical bond of  some sort. People 
have already mentioned the Polyphaser TK. It works  great.
 
Cheers,
Steve     K7LXC