| k6tfz@aol.com wrote:
> I have 150 feet of 15 year-old Rg-214 still up. I measured the power in at 
> 50W and the power out (at the other end) at 36.6W using a dummy load 
> terminator of 50 ohms. As it still good or should I change it? I would be 
> interested in the calcs. I already did mine but want to be sure.
>   
db loss = 10log(50/36.6)=1.3549/150ft=*100=0.90 db/100 ft which ain't 
bad if you did the test on 14 MHz.  It's far too good for 30 Mhz.
73
Roger (K8RI)
> Thank you.?? Geoff, K6TFZ
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
>
>   
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
 |