| 1.36 dB loss according to my windoze calculator. Only you can determine if 
that is good enough for your needs or not.
Gedas, W8BYA
http://gedas.cc
http://www.w8bya.com
----- Original Message ----- 
From: <k6tfz@aol.com>
To: <towertalk@contesting.com>
Sent: Saturday, April 12, 2008 4:22 PM
Subject: [TowerTalk] Coax Line Loss
>I have 150 feet of 15 year-old Rg-214 still up. I measured the power in at 
>50W and the power out (at the other end) at 36.6W using a dummy load 
>terminator of 50 ohms. As it still good or should I change it? I would be 
>interested in the calcs. I already did mine but want to be sure.
> Thank you.?? Geoff, K6TFZ
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk 
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
 |