One thing has been overlooked in the discussion of grounding with respect to lightning and ac safety. I don't disagree with anything W3LPL had to say, but I would like to point out that it is important to keep all of the equipment close to the same RF potential as possible. This prevents RF feedback and circulating current between pieces of equipment. Connecting all of the equipment together with a low-impedance strap is a good way to accomplish this.

Note that you probably can't make that RF potential equal to zero because of the length of the connection between the strap and earth. That doesn't matter, you just want the radio, the tuner, the audio mixer, whatever, to be at the SAME potential to prevent current flow between their chassis. This is a particular problem with "second story" shacks where a connection to true ground may be meters long. At multi-position stations, it's also impossible to keep all the equipment at the same potential and so you have to settle for keeping the equipment at each position at the same potential, even though that may be many volts different than one of the other positions.

73, Ward N0AX


_______________________________________________


See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>