> meter...Anybody had this kind of problem or any ideas what to look
> for...This volatage on all pins no matter position the switch is in
> ,is really throwing me...Thanks for any and all help....... Ted   
> K9HUH

If you have anywhere over one volt on all the pins you most likely 
have an open ground between the relay box and the RCS-8 control 
unit. The other option is all the leads are shorted, and that is 
unlikely.


73, Tom W8JI
W8JI@contesting.com 

List Sponsored by AN Wireless:  AN Wireless handles Rohn tower systems,
Trylon Titan towers, coax, hardline and more. Also check out our self
supporting towers up to 96 feet for under $1500!!  http://www.anwireless.com

-----