To: | <topband@contesting.com> |
---|---|
Subject: | Re: Topband: Modeling "Ground" |
From: | "Tom W8JI" <w8ji@w8ji.com> |
Reply-to: | Tom W8JI <w8ji@w8ji.com> |
Date: | Mon, 23 Feb 2015 07:58:13 -0500 |
List-post: | <topband@contesting.com">mailto:topband@contesting.com> |
In reality, NEC4 can produce quite accurate results when modeling buried radial wires and groundwave propagation losses along a real earth path -- as long as earth conductivity is known for that path and operating frequency. Calculating a good result for one situation, like field strength at a distance for a vertical radiator when gradual attenuation is involved, is worlds different than calculating pattern produced by a long buried wire. _________________ Topband Reflector Archives - http://www.contesting.com/_topband |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: Topband: Modeling "Ground", Richard Fry |
---|---|
Next by Date: | Re: Topband: RX cables in woods, Tom W8JI |
Previous by Thread: | Re: Topband: Modeling "Ground", Richard Fry |
Next by Thread: | Re: Topband: Modeling "Ground", K1FZ-Bruce |
Indexes: | [Date] [Thread] [Top] [All Lists] |