Topband
[Top] [All Lists]

Topband: Beverage strain

To: <topband@contesting.com>
Subject: Topband: Beverage strain
From: "Bruce" <k1fz@myfairpoint.net>
Date: Sun, 22 Jul 2012 08:55:08 -0700
List-post: <topband@contesting.com">mailto:topband@contesting.com>
It's almost enough to drive one back to electric fence wire. It's 
inexpensive and reconnects easily using the wireman splice.
73
Bruce-K1FZ

 On 07/20/2012 12:59 PM, Tom W8JI wrote:
 This is exactly the problem I have with Wireman stranded ~400 ohm ladder
 line. After a few years, if water gets inside, conductors  rust through.

 If water gets into WD1A, the three steel strands rust through in
 less than 6 months. Sometimes much less. The four tinned copper
 strands deteriorate and eventually break also. I'm not a
 metallurgist, but somehow the rust from the steel *seems* to weaken
 them.


 73,
 Paul N1BUG
> _______________________________________________
> UR RST IS ... ... ..9 QSB QSB - hw? BK
> 

_______________________________________________
UR RST IS ... ... ..9 QSB QSB - hw? BK

<Prev in Thread] Current Thread [Next in Thread>