TenTec
[Top] [All Lists]

Re: [TenTec] Orion II Cold Start Problem

To: NZ3O@arrl.net, Discussion of Ten-Tec Equipment <tentec@contesting.com>
Subject: Re: [TenTec] Orion II Cold Start Problem
From: "Peter Frenning [OZ1PIF]" <peter@frenning.dk>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Sun, 07 Jun 2015 12:51:18 +0200
List-post: <tentec@contesting.com">mailto:tentec@contesting.com>
Den 07-06-2015 kl. 07:48 skrev Byron Peebles:
I have a problem with an Orion II when first powered on.

The unit begins to come up:
    1. Screen comes on, displays TT Logo, Firmware Revisions and so on.
2. As the unit completes that boot, the S-Meter lights and the screen goes out. 3. With the screen out, there is nothing lit on the front panel. No selection lights at all. 4. If the screen stays lit, the lights are lit, but the main receiver seems muted. 5. With the main receiver muted, there is no transmit capability through either VFO. 6. I can hear on the sub-receiver (standard sub, not optional sub) but not transmit on it.

Is this a problem that will involve the factory?

TIA es 73, Byron

PS. Did Master Rest, Memory Clear, Firmware Update, Rinse and Repeat.
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

Mine did exactly the same, electrolytic caps on the A9 (Power distribution) board are the most likely culprit, they need to be replaced with the best you can find (125°/Low ESR types) you might as well do them all (5 if my memory serves me right) at once, if the aren't gone already they will go eventually)


--
Vy 73 de OZ1PIF/5Q2M, Peter

******************************************
** If it sounds too good to be true --  **
** it is!                               **
** If it sounds about right -- make     **
** sure you can afford to be wrong!     **
**                                      **
**           -- Robert Heinlein:        **
**           "Time enough for love"     **
******************************************
email: peter(no-spam filler)@frenning.dk
http://www.frenning.dk/oz1pif.htm
Ph. +45 4619 3239/ +45 2332 9464
Snailmail:
Peter Frenning
Ternevej 23
DK-4130 Viby Sj.
Denmark
******************************************

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>