I would start by replacing capacitors on the power distribution board:
http://tentecwiki.org/doku.php?id=565pwrdistfail
73, Barry N1EU
On Sun, Jun 7, 2015 at 5:48 AM, Byron Peebles <NZ3O@arrl.net> wrote:
> I have a problem with an Orion II when first powered on.
>
> The unit begins to come up:
> 1. Screen comes on, displays TT Logo, Firmware Revisions and so on.
> 2. As the unit completes that boot, the S-Meter lights and the screen
> goes out.
> 3. With the screen out, there is nothing lit on the front panel. No
> selection lights at all.
> 4. If the screen stays lit, the lights are lit, but the main receiver
> seems muted.
> 5. With the main receiver muted, there is no transmit capability
> through either VFO.
> 6. I can hear on the sub-receiver (standard sub, not optional sub) but
> not transmit on it.
>
> Is this a problem that will involve the factory?
>
> TIA es 73, Byron
>
> PS. Did Master Rest, Memory Clear, Firmware Update, Rinse and Repeat.
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
>
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|