I tried it a few times.  When power is turned back on, it resets to  
default values of 100 on CW and 3000 on SSB.  Definitely a bug.
 
73 Ray W2RS
 
 
In a message dated 6/17/2010 6:00:33 P.M. GMT Standard Time,  
skline4@verizon.net writes:

Last  night I observed a problem somewhat similar to what Rick is  
describing.

I noticed that what ever setting the variable BW is reading  prior to 
shutting the radio off is not the same BW setting that is restored if  you turn 
the radio off and then turn it back on.  For example if I was in  SSB mode, 
with BW set to 3000 and then turn the radio off and then back on;  after 
boot-up the BW setting may come up as 2480 or some other number but not  3000 
where it was at prior to shut down.  Same occurs in CW mode, and can  be 
replicated.

Maybe related to same problem below.  Can anyone  else validate the power 
on/off sequence and confirm if their BW setting was  restored to same value 
as it was before turning the power off?   

Thanks 
Steve - W5JK

On Jun 17, 2010, at 8:39 AM, Rick  Borken wrote:

> Here are three bugs which I have found in the recent  2.044A firmware 
update. 
> I have reported them to Ten-Tec:
>  
> The fix "fixed restoration of bandwidth when recalling USER memory"  does 
not
> work correctly in v 2.044A. It behaves differently than it  did in 2.043, 
but 
> it is still incorrect.
> When I recall a USER  memory, the bandwidth always gets set to 1000 Hz 
for 
> CW, 2400 Hz for  FSK and 100 Hz for SSB. It
> does not reset to the value I tried to  store in a USER memory.
> 
> When I push the RECALL button and  then recall the Factory Default USER
> settings, the resulting screen  shows PWR set to 100, and the value of 
PWR 
> is "frozen,"
> and  cannot be changed in the normal way by highlighting the
> value and  adjusting it with the MULTI knob.
> 
> in v 2.044A, the value of  "AGC Hang" is  not restored to the value 
stored in
> the USER  memory when recalling a USER memory.
> 
> 73, Rick K0XB
>  
> 
> 
> 
> 
>  _______________________________________________
> TenTec mailing  list
> TenTec@contesting.com
>  http://lists.contesting.com/mailman/listinfo/tentec

_______________________________________________
TenTec  mailing  list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>