To: | rfi@contesting.com |
---|---|
Subject: | Re: [RFI] Portable Generator Noise |
From: | Jim Brown <jim@audiosystemsgroup.com> |
Reply-to: | jim@audiosystemsgroup.com |
Date: | Sat, 16 Jul 2022 15:31:40 -0700 |
List-post: | <mailto:rfi@contesting.com> |
On 7/16/2022 3:04 PM, Bob Turner wrote: The SMPS (converter) in my Travel Trailer does make RFI. Fortunately it falls off quickly with distance. At least 10 years ago, when N6RNO brought his fairly large RV to CQP, we rigged a multi-turn choke on a 2.4-in o.d. Fair-Rite #31 into the DC distribution line to kill the noise from the DC-AC inverter. Winding guidelines same as for parallel wire transmitting chokes at k9yc.com/publish.htm 73, Jim K9YC _______________________________________________ RFI mailing list RFI@contesting.com http://lists.contesting.com/mailman/listinfo/rfi |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [RFI] Portable Generator Noise, Don Kirk |
---|---|
Next by Date: | [RFI] Lennox brand HVAC RFI experience, Jeff Blaine |
Previous by Thread: | Re: [RFI] Portable Generator Noise, Bob Turner |
Next by Thread: | Re: [RFI] Portable Generator Noise, Jim Brown |
Indexes: | [Date] [Thread] [Top] [All Lists] |