Sounds very similar to the problem we're having right now.    This past time
we went 48 hours before it happened again, only for me, a simple reboot
won't do it, I have to change channels...weird.

Answer me this:

what hardware platform are you on?  AP1000, KN200, Flashrom

What are your clients using for hardware and how many are there?  Do you
have any KN50's in the mix?

I am very interested to hear your answers, as I'm sure Reg will be as well.

----- Original Message ----- 
From: "Karlnet Posting Promo Systems" <karlnet@promosystems.nl>
To: <karlnet@wispnotes.com>
Sent: Thursday, January 29, 2004 3:23 PM
Subject: [Karlnet] Hang up of the cell


> Hello
>
> We have a large network in holland created with Turbocell
> On this moment we have a strange problem with a POP location.
>
> The site situation is described as below.
>
> The problem is: The 2 cells works normal, ping times to the users are 20ms
> average.
> Sometimes in the cells the ping times go from 20ms
> -100-500-600-1200-2000-timeout
> The interface monitor on the base says that the traffic is normal (100
> -300KByte/s)
> But the user don't get much data en the ping times goes from timeout -
2400ms
> - timeout
>
> When I reset cell 2 the situation goes back to normal, pingtimes are back
to
> 20 - 30ms
> Sometimes after cell 2 is back from reboot the same happens again (3-4
times)
> Other times the cells stays good for several hours and then it happens
again.
> Resetting the switch does the same.
>
>
>
> We have set the eth interfaces to full duplex / 10Mbit on advice of
Karlnet
> but it doesnt help.
>
> Does anyone an idea, please let me know
>
> Marco Eegdeman
> Marco@promosystems.nl
>
> --------------
>
> Site Situation
>
> In the beginning we used ap1000 and wavepointII.
> After the RG+ came available we replaced the WPII with the RG+ (KN100)
>
> Now we have a location with 2 cells and a PTP all on 2,4Ghz
> The PTP is no TurboCell
> Cell 1 = Ch1  (KN100)
> Cell 2 = Ch9  (KN202) new RG+
> PTP = Ch13
>
> Our Network on that location is:
>
> PTP => Linux Router => Switch => KN100 and a KN202 base ISP
>
> Our clients are bridged from the cell (RG1100 and Ubicom about 25 clients
in
> each cell) to the base, from there the are routed to the Internet.
>
> 80% of the clients are NAT routed bij the linux router.
> 20% of the users have a Public IP and are also routed bij the linux router
>
> We use the latest firmware 4.44.01 in the RG+ and the RG1100. The ubicoms
are
> of course factory default
>
> _______________________________________________
> Karlnet mailing list
> Karlnet@WISPNotes.com
> http://lists.wispnotes.com/mailman/listinfo/karlnet
>

_______________________________________________
Karlnet mailing list
Karlnet@WISPNotes.com
http://lists.wispnotes.com/mailman/listinfo/karlnet

<Prev in Thread] Current Thread [Next in Thread>