The transformer you sent the link for is this one:
Output Voltage Current
800V .50A
*800 VAC X 2.8 (for a voltage doubler) is 2240 volts DC. ********How do you get
3500 volts+ of out that?*****
Thanks
73
Jim W7RY
On 10/30/2019 9:05 PM, Joe wrote:
Umm Nope, 3500+ The plate voltage meter is not quite HARD pegged but
easily over full scale.
When testing at lower voltages for the in vs out ratios and with the
in that I have I'm calculating close to 3650
Joe WB9SBD
On 10/30/2019 8:00 PM, Jim wrote:
And it only produces 2240 volts DC. A bit low for an SB220....
Thanks
73
Jim W7RY
On 10/30/2019 1:38 PM, Joe Subich, W4TV wrote:
>> https://www.antekinc.com/as-8t800-800va-transformer/
Unfortunately, this transformer lacks the primary taps for CW/SSB
operation of the OEM device.
73,
... Joe, W4TV
On 2019-10-30 10:23 AM, Joe wrote:
On 10/30/2019 8:56 AM, Joe wrote:
Morning Dick,
If you are not afraid of making a few electrical and mechanical
modifications, I would go with this transformer.
https://www.antekinc.com/as-8t800-800va-transformer/
I'm glad I did! 1/4 the cost of most drop in replacements. yet
MUCH better performance!
Joe WB9SBD
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|