That relay is fine for switching coil taps but doesnt appear to be what you
need unless you wire sections in parallel and use a relay for each band.
Since youre switching at a low RF voltage point the main concern is RF
current handling and that relay looks to be overkill.
Carl
KM1H
----- Original Message -----
From: <qrv@kd4e.com>
To: <amps@contesting.com>
Sent: Thursday, April 17, 2014 3:04 PM
Subject: [Amps] Is this relay suitable for 1kw+ RF?
I recently acquired one of these 3PDT relays:
http://www.ebay.com/itm/Leach-Relay-Model-1177-CBF-115-Volt-50-60-Cycles-Coil-374-New-Old-Stock-/121209541061
I have an application to cold-switch sections of coil inline with
my 43' ZeroFive vertical to help with tuning on 160 + 80m.
Anyone know if this relay would be suitable to the task at full
legal ... or for that matter for RF in that application at all?
Thanks ... David KD4E
--
David (NOT Dave) Colburn, KD4E - Nevils, Georgia USA