Doug,
Depending on the type of bleeder, you might consider connecting the
voltmeter near the bottom of the bleeder string.
73s de Jim
W5IFP
> -----Original Message-----
> From: Amps [mailto:amps-bounces@contesting.com]On Behalf Of Douglas
> Johnson
> Sent: Saturday, November 03, 2012 4:16 PM
> To: AMPS
> Subject: [Amps] plate voltage meter shunt
>
>
> I am installing a meter to measure plate voltage 1-5000v@ 1a
> dc, the meter has a 1ma fs rating. the serial resistance I
> have made up in the past has been 3 watt metal film resistors
> in series. since they can only rated for 200v per resistor it
> takes many to do the job. Can some other resistor type with a
> higher rating be used in a safe manner for this purpose?...tnx,
> Doug,w9iix
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps