Mouser carries Ohmite flatpak HV resistors; Ive been using them to replace the old carbons in many amps.

Carl
KM1H


----- Original Message ----- From: "Douglas Johnson" <w9iix1@yahoo.com>
To: "AMPS" <amps@contesting.com>
Sent: Saturday, November 03, 2012 5:15 PM
Subject: [Amps] plate voltage meter shunt


I am installing a meter to measure plate voltage 1-5000v@ 1a dc, the meter has a 1ma fs rating. the serial resistance I have made up in the past has been 3 watt metal film resistors in series. since they can only rated for 200v per resistor it takes many to do the job. Can some other resistor type with a higher rating be used in a safe manner for this purpose?...tnx, Doug,w9iix