Amps
[Top] [All Lists]

Re: [Amps] amps with vacuum pumps

To: amps@contesting.com
Subject: Re: [Amps] amps with vacuum pumps
From: "Joe Subich, W4TV" <lists@subich.com>
Date: Wed, 02 May 2012 11:25:06 -0400
List-post: <amps@contesting.com">mailto:amps@contesting.com>
In most cases, heat pipe systems (and that's what one would have with
an evacuated vapor system) require a secondary heat exchanger.  The
low pressure system moves the heat from where it's generated to a
heat exchanger where it is transferred to a second cooling medium that
can be moved a longer way to the final heat exchanger.

The rigid pipes and initial heat exchanger might be a construction and
maintenance issue for amateur equipment - and probably not worth the
incremental performance vs. a more traditional radiator/reservoir
design.

73,

    ... Joe, W4TV


On 5/2/2012 11:12 AM, Pete Smith N4ZR wrote:
> Perhaps someone with practical experience can comment on whether it is
> hard to maintain a 1 PSI vacuum in a vapor system.
>