2100v is too much for 811As. The HV PS power supply's regulation can be
improved for SSB by resonating the filter choke at 120Hz with a cap.
However, for AM there is no benefit.
Another improvement is to remove the RCA "neutralization" circuitry
since it is know to cause VHF surprises.
On Mar 23, 2006, at 9:04 AM, Jim Tonne wrote:
>
> If that 50k resistor is the bleeder on the power supply,
> * leave it alone * !!!
>
>> I had been thinking that changing the HV supply from
>> choke input to capacitor input would boost the HV up
>> to 2100 V and eliminate the need for the 50k 100W
>> load resistor (it adds 45W of extra heat).
>
> - Jim WB6BLD
>
>