Amps
[Top] [All Lists]

Re: [Amps] For cats sake!

To: amps@contesting.com
Subject: Re: [Amps] For cats sake!
From: "Will Matney" <craxd1@verizon.net>
Reply-to: craxd1@verizon.net
Date: Sun, 05 Mar 2006 23:11:45 -0500
List-post: <mailto:amps@contesting.com>
Bill,

It's according to how you hook it up. If you connect one end of the variacs 
winding to the line, and the output to the wiper (going to the load), leaving 
the other side of the variacs winding unconnected, you have a variable choke. 
All it is, is a round iron core toroid, with magnet wire wrapped around it, and 
a wiper running across the bare magnet wire on the back side. If you use both 
ends of the coil (both to the line), and the wiper as out, you have a variable 
autotransformer. It will work either way. Generally, I always use them as a 
variable choke, and have ran several motors that way by converting the output 
AC to DC with rectifiers, and hooking that to a DC PM motor. All you have then 
is a big variable voltage DC supply. The old Hobart mig wire feeders worked the 
same way. That's how I powered my winding lathe too, and worked like a charm. 
In his case, he could use a choke to drop the line voltage some, however it 
will raise the current in the primary. He can use it o
 n the secondary side too providing the wire and paper in the choke can stand 
up to the HV (if it's insulated enough). Last he could buck the HV winding with 
a transformer that has a secondary of the right value. I personally don't like 
that route though because of the expense. A choke or variac is most likely 
cheaper than a transformer.

Best,

Will

*********** REPLY SEPARATOR  ***********

On 3/5/06 at 7:49 PM Bill Turner wrote:

>ORIGINAL MESSAGE:
>
>At 04:45 PM 3/5/2006, Will Matney wrote:
>>That or a choke with enough inductive reactance to drop the voltage 
>>as that's all a variac is.
>
>~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
>Can't believe you said that, Will.
>
>A variac is a transformer, not a choke. With a choke, the amount of 
>voltage drop depends on the amount of current drawn, while with a 
>variac it does not.
>
>73, Bill W6WRT
>
>_______________________________________________
>Amps mailing list
>Amps@contesting.com
>http://lists.contesting.com/mailman/listinfo/amps



_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps