Hi Mike
 
I think the breakdown for air is 75V/mil... about 9kV @ 125 mils.
 
Engineers would probably then down-rate it (fudge factor) to maybe 6 or  7kV. 
 Check the ARRL Handbook.  It has a list of common spacings and  their 
voltage ratings.
 
Give ya 5 buckos fer it there buddy.  ;-))
 